Conair Hopper Temperature Controller UGD031 User Manual

Page 19

Advertising
background image

D e s c r i p t i o n l

2 - 7

S p e c i f i c a t i o n s : H T C f o r H o t A i r D r y e r s ( H A D )

A

B

C

D

E

F

H

G

I

2

Description

MODEL HTC

HTC-30B*

HTC-30A*

HTC-60A*

HTC-90A*

HTC-120A*

HTC-180A*

Hot air dryer mode

l

600 800

1000

1600

2400

3200

5000

Performance characteristics

Temperature range

120° - 250° F {49° - 121° C}

Flow rate cfm

300 400

500

800

1200

1600

2500

Pressure drop@flow rate

inches WC

3.0 5.0

3.2

5.4

6.1

6.4

8.0

{mm} WC

{76.2} {127}

{81.2}

{137.2}

{155.0}

{163.0}

{203.2}

Dimensions inches {cm} and weight lb {kg}

Heater box dimensions

Inlet size (OD)

5

5

8

8

8

12

Outlet size selection (OD)

5

5

8

8

8

12

A - Height

31.4 {79.8}

27.5 {69.9}

27.5 {69.9}

32.0 {81.3}

31.0 {79.0}

34.0 {86.3}

B - Width

10.1 {25.7}

13.6 {34.5}

13.6 {34.5}

15.9 {40.4}

16.0 {40.6}

18.0 {45.7}

C - Depth

10.7 {27.2}

10.7 {27.2}

10.9 {28.0}

16.0 {40.6}

17.0 {43.2}

20.0 {50.8}

D - Height of discharge

0 {0}

5.9 {15.0}

2.0 {5.1}

1.0 {2.5}

2.0 {5.1}

1.0 {2.5}

nozzle above heater box

E - Height of inlet nozzle
below the heater box

8.0 {20.3}

11.4 {30.0}

8.0 {20.3}

11.0 {27.9}

13.0 {33.0}

13.0 {33.0}

Installed weight lb {kg}

37 {17}

58 {26}

78 {35}

93 {42}

102 {46}

131 {59}

Control center dimensions

F - Height

24.0 {61.0}

24.0 {61.0}

24.0 {61.0}

36.0 {91.4}

48.0 {122.0}

60.0 {152.4}

G - Width

24.0 {61.0}

24.0 {61.0}

24.0 {61.0}

30.0 {76.2}

36.0 {91.4}

42.0 {106.7}

H - Depth

10.0 {25.4}

10.0 {25.4}

10.0 {25.4}

10.0 {25.4}

10.0 {25.4}

12.0 {30.5}

I - Clearance for heat sink

3.0 {7.6}

3.0 {7.6}

3.0 {7.6}

3.0 {7.6}

3.0 {7.6}

3.0 {7.6}

Installed weight lb {kg}

150.0 {68.0}

150.0 {68.0}

150.0 {68.0}

180.0 {81.6} 250.0 {113.0}

consult Conair

Voltage Current Amps

400V/3 phase/50-60 Hz

43.3

43.3

86.6

129.9

173.2

259.8

460 V/3 phase/50-60 Hz

37.7

37.7

75.4

113.1

150.8

226.2

575 V/3 phase/50-60 Hz

30.1

30.1

60.2

90.3

120.4

180.6

SPECIFICATION NOTES:

*

The HTC model number reflects the kilowatts of each unit. For example, HTC-60 has a 60 kilowatt heater.

The unit of measure WC is water column.

Specifications may change without notice. Consult a Conair representative for the most current information.

TPDS024-0106