6 - 4

l Tr o u b l e s h o o t i n g

H o w t o I d e n t i f y t h e C a u s e o f a
P r o b l e m

Most heater malfunctions are indicated by an illuminated Alarm light on the HTC
process air heater control panel.

A problem can trigger two types of alarms:

Shut Down: The heater has automatically shut down because it detected a

serious problem that could damage your material or dryer.

Passive: The heater continues to operate, but warns of a problem that could

prevent correct heating of your material. If ignored, this problem could lead to
a condition that will shut down the dryer.

When the alarm light is displayed:

1

Press the Acknowledge Alarm button to silence the alarm (see page
4-2).

2

Find the error message in the diagnostics table of this Troubleshooting
section.

3

Cycle the heater switch from Enable to Standby and then back to

Enable to clear and restart normal control. If the alarm reappears, the
problem was not fixed.

Heaters

Startup /

Shutdown

For Startup:

1. With heaters in
Standby, turn on
blower or dryer.
2. Enable heaters.

For Shutdown:

1. Switch heaters to
Standby.
2. Wait 60 seconds
before turning off
blower or dryer.

Enable

Standby

Alarm Light

Acknowledge Alarm
Button