Conair Hopper Temperature Controller UGD031 User Manual

Page 54

Advertising
background image

4 - 1 8

l O p e r a t i o n

C o n t r o l F u n c t i o n D e s c r i p t i o n s

( c o n t i n u e d )

Te s t M o d e
S c r e e n s *

SCREEN 50

SCREEN 52

SCREEN 53

F u n c t i o n

This is the output 3 screen. Press the "+"
key to jog output 3. Output 3 on a heater
is the process heater solid-state relay sig-
nal. Pressing the "+" key will cause the
process solid-state relays to fire. You can
observe the solid-state relay LED to check
this output. Since the isolation contactor is
open, the heater does not come on because
it does not have power.

This is the output 5 screen. Press the "+"
key to jog output 5. Output 5 on a heater
is the process heater power isolation con-
tactor signal. Pressing the "+" key will
cause the isolation contactor to close.
Watch the isolation contactor pull in to
check this output. Since the solid-state
relays are not on, the heaters does not
come on because they do not have power.

This is the output 6 screen. Press the "+"
key to jog output 6. Output 6 on a heater
is the alarm horn. Pressing the "+" key
will cause the alarm horn to sound.

ou.3

OFF

ou.6

OFF

ou.5

OFF

* Outputs 1, 2, and 4 are not used

in the HTC.