Conair Hopper Temperature Controller UGD031 User Manual

Page 40

Advertising
background image

POWER ON

1

888

888

2 sec All LEDs On

2

dC

004

2 sec Software Version

3

res

in

(Default Screen)

4

250

250

Process Setpoint and Actual Temp (Default Screen)

Press + or - to change setpoint.

Press Scroll Button for Process Deviation Alarm Setpoint (Dev)

5

5dEv

+ or - Deviation Band

Press + or - to change setpoint.

Press Scroll to enter the value

Process Screens

Process Protection Screens

Press Scroll Button and + key at the

Press Scroll Button and + key at the

same time for 2 sec to get in.

same time again for 2 sec to get in.

To get out at any time Press Scroll

To get out at any time Press Scroll

button and - key at the same time

button and - key at the same time

2 Min timer then return to the default screen

6

Pro

cES

16

Pro

tEc

Press Scroll again to view next screen

Press Scroll again to view next screen

7

375

Hi.L

Process High Limit

17

Act

250

Protect Temperature

Press Scroll again to view next screen

Press Scroll again to view next screen

8

3

Lbb

Process Loop Break Band

18

625

H.Al

Protect Hi Alarm SP

Press Scroll again to view next screen

Press Scroll again to view next screen

9

10

Lbt

Process Loop Break Time

19

10

H.dL

Protect Hi Alarm Delay

Press Scroll again to view next screen

Press Scroll again to view next screen

10

385

H.AL

Process High Alarm Setpoint

20

300

d.AL

Differential Alarm SP

Press Scroll again to view next screen

Press Scroll again to view next screen

11

50

Pb

Process Prop

21

80

d.dL

Differential Alarm Delay

Press Scroll again to view next screen

12

16

int

Process Integral

Press Scroll again to view next screen

Press Scroll again to view the first screen

13

2dEr

Process Derivative

Press Scroll again to view next screen

14

tun

OFF

Process Autotune

Press + Key to Start Autotune

Press Scroll again to view next screen

15

F

unt

Units degrees F or degrees C

Press + Key to toggle between F and C

Press Scroll again to view the first screen

Press Scroll Button again for Setback
Return Temperature Setpoint

5A

180

Srt

Press Scroll Button again for Process
Setback Temperature Setpoint

5B

140

PSt

Press Scroll to enter the value

(Optional)

Press + or - to change setpoint.

Press Scroll to enter the value

Press + or - to change setpoint.

4 - 4

l O p e r a t i o n

Advertising
This manual is related to the following products: