Section 4.1- cooling system familiarization, Introduction, Recommended coolant – Generac 86640 User Manual

Page 53: High coolant temperature switch, Description, Testing high temperature shutdown, Testing the switch

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section 4.1- COOLING SYSTEM FAMILIARIZATION

Introduction

The generator cooling system is of the closed recovery

type. Major cooling system components consist of (a) radia­
tor, (b) coolino fan, (c) coolant recovery bottle, (d) engine

water pump, (e) thermostat, and (f) interconnecting hoses.

Recreational vehicle generators are typically housed in

a compartment. An adequate flow of cooling, combustion and
ventilating air must be provided for these compartments.

Some models are equipped with unit-mounted radiators.

Other models may have remote mounted radiators.

At least one IM (Industrial Mobile) generator model is

equipped with a heat recovery system.

Recommended Coolant

Recommended Is a 50-50 mixture of low silicate ethylene

glycol base anti-freeze and soft water for all-weather protec­
tion. If desired, a high quality rust inhibitor may be added to
the recommended mixture. When adding coolant to the radi­

ator or to the coolant r4ecovery bottle, always add the recom­
mended 50-50 mixture.

NOTE: Cooling system capacity for models with unit-
mounted radiator Is approximately 2.5 U.S. gallons (9.5
liters). Use only SOFT water and LOW SILICATE anti­
freeze. For Installations equipped with a remote-mounted

radiator, cooling system capacity will depend on radiator
hose lengths.

The switch contacts should close and switch should read

“continuity“ at about 225‘-235’ F. (107'-113‘ C.).

CAUTION: The use of any "chromate" base Inhib­
itor is NOT recommended. When chromate base

rust inhibitor is used with ethylene glycol base
anti-freeze, chromium hydroxide Is formed in the
cooling system. Chromium hydroxide Is visible to
the eye as a "green slime" which can cause re­
duced heat transfer and possible overheating. Any

cooling system that has been operated with a
chromate

base

inhibitor

must

be

chemically

cleaned before adding ethylene glycol base anti­
freeze. Use of any high silicate anti-freeze boost­
ers or additives is NOT recommended. In addition

to the preceding, the use of any soluble oil rust
inhibitor Is NOT recommended.

High Coolant Temperature Switch

DESCRIPTION:

The engine mounts a normally-open (N.O.) thermostatic

switch (Figure 1). The sensing tip of the switch is normally
immersed in engine water jacket coolant. Should coolant
temperature exceed approximately 230' F. (110* C.), the
switch contacts will close and the engine will shut down
automatically.

TESTING HIGH TEMPERATURE SHUTDOWN:

To test the high temperature shutdown feature, first

disconnect Wire No. 85 from the switch terminal. Start the
engine, let it stabilize and warm up at no-load. Hold the
terminal end of Wire No. 85 into contact with a clean frame
ground on the engine. After a short delay, the engine should
shut down.

TESTING THE SWITCH:

Remove the switch. Check the switch closing tempera­

ture with an ohmmeter (Figure 2).