Section 9.3- ENGINE CRANKING SYSTEM

Cranking System Description

See Figure 7, below. Battery power is available to a

large terminal stud of the STARTER CONTACTOR. How­
ever, the STARTER CONTACTOR contacts are normally-
open. From the STARTER CONTACTOR, battery voltage is
available to the ENGINE CONTROL circuit board, via Wire

13, a 10 amp CIRCUIT BREAKER, and Wire 15. Major

components of the engine cranking system include the fol­

lowing:

D Engine control circuit board.

D

Start-Stop switch,

n 10 amp Circuit Breaker.

CD

Starter Contactor,

n Starter.

CD

12 volts Battery.

Figure 7. Engine Cranking System Diagram

Operational Analysis

Operation of the engine cranking system may be briefly

descrioed as follows (Figure 7):

1. Battery power is available to the STARTER CONTACTOR,

via the positive battery cable. Battery power is also available
to the ENGINE CONTROL circuit board, via Wire 13, a 10
amp CIRCUIT BREAKER, and Wire 15.
2. When the START-STOP SWITCH is set to “Start", Wire 17
and Pin 3 of the ENGINE CONTROL board are connected to
ground. Circuit board action then delivers 12 volts DC to the
STARTER CONTACTOR coil, via Wire 56. The STARTER
CONTACTOR is energized and its contacts close.
3. On closure of the STARTER CONTACTOR contacts, 12
volts DC is delivered to the STARTER. The engine cranks.
4. When the engine starts, the START-STOP SWITCH is

released and Wire 17 is no longer grounded. Circuit board

action opens the 12 volts DC circuit to Wire 56 and cranking
terminates.

Engine Control Circuit Board

See Section 9.4, "ENGINE CONTROL CIRCUIT.

Start-Stop Switch

DESCRIPTION;

See Figure 8. Wires 17 (start), 18 (stop), and 0 (ground)

connect to the start-stop switch terminals.

Setting the switch to "Start" connects the Wire 17 circuit

to Wire 0 (ground). Engine control circuit board action then

initiates engine cranking and startup.

Setting the switch to "Stop" connects the Wire 18 circuit

to ground. The circuit board.then opens its circuit to Wire 14
and engine shutdown occurs.

TESTING THE SWITCH:

The start-stop switch can be tested using a volt-ohm-mil-

liammeter (VOM). Set the VOM to its "Rxl" scale and zero
the meter.

D Connect the VOM test leads across the Wire 17 and the

Wire 0 terminal of the switch. With switch at “Start", the

meter should read "continuity": at “Stop", switch should
read “infinity".

D Connect the VOM test leads across the Wire 18 and the

Wire 0 terminals of the switch. Set switch to “Start" and

meter should read “infinity". Set switch to “Stop" and it
should read “continuity”.

10 Amp Circuit Breaker

Refer to Section 9.4, "ENGINE CONTROL CIRCUIT.

Starter Contactor

DESCRIPTION:

The starter contactor (or starter solenoid) is attached to

the engine-generator control panel. See Figure 9.

TESTING THE STARTER CONTACTOR:

If the engine will not crank, the starter contactor can be

tested as follows:

1. Check for normal battery voltage at the large terminal stud

to which the positive battery cable connects.

a. If battery voltage is zero or low, check the battery cable
and the battery.
b. If normal battery voltage is read, go on to Step 2.

Page 9.3-1

Advertising