Section 9.4- ENGINE CONTROL CIRCUIT

Engine Control Circuit Board

An engine control circuit board (Figure 11), noused in the

generator control panel, controls engine starting, running and
shutdown functions. A 12 volts DC power supply is delivered
to the board for control of those functions.

Circuit board terminals, connecting wires and a descrip­

tion (or function) of the wires is listed in the following chart:

TERMINAL

WIRE

DESCRIPTION OR FUNCTION

1

15

Breaker protected 12 volts DC power

to operate engine control system.

2

0

Common ground.

3

17

Engine will crank when this circuit

is grounded.

4

18

Engine will shut down when this

circuit is grounded.

5&6

11, 22

Frequency (engine speed) signals

from generator AC power leads for

automatic engine shutdown.

7

56

Crank signal- starter contactor

energizes when circuit board

energizes Wire 56 circuit.

8

9

Delivers 12 volts DC to ignition

coil for engine cranking only.

9

14

Delivers 12 volts DC to carburetor

fuel valve, fuel pump and DC alter­

nator for running.

10

RW

Once cranking has ended, battery

power Is delivered to the Ignition

coil via a resistance wire.

11

14

Delivers 12 volts DC to a

remote panel only when the

engine is running.

12

85

When this circuit Is grounded by

closure of either (a) a low oil

pressure switch, or (b) a high

coolant temperature switch, an

automatic engine shutdown will

occur

Figure 12. Engine DC Control Circuit