Cabletron Systems SPECTRUM FRX6000 User Manual

Page 58

Advertising
background image

Configuring the Trap Table

3-8

Trap Messages

Trn Port Usage exceeded T: “n” C: “n”

319

The port statistic % Transmit Port Utilization has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)

Severity

Informational (Level 4)

Action

If this happens frequently, you may need to add ports or reroute
some trafÞc.

Receive Yellow Alarm Condition Set

338

A Yellow Alarm was received.

Severity

Major (Level 2)

Action

Contact your T1 carrier.

Receive Yellow Alarm Condition Set

339

The condition that caused event 338 has been cleared

Severity

Informational (Level 4)

LIC “n” Installed, Not Configured

377

The speciÞed Line Interface Card (LIC) exists in the node, but has not been
conÞgured in the Line Processor Þle.

Severity

Minor (Level 3)

Action

ConÞgure the LIC or remove it from the node.

LIC “n” Configured, Not Installed

378

The speciÞed Line Interface Card (LIC) has been conÞgured in the Line Processor
Þle, but does not exist in the node.

Severity

Critical (Level 1)

Action

Install the LIC or delete its record.

LIC “n” Config Mismatch—Type “n”

379

The interface type of the speciÞed Line Interface Card (LIC) installed in the node
is different from the interface type conÞgured in the Line Processor Þle. As a
result, the software does not load properly and will not operate.

Severity

Major (Level 2)

Action

Change either the card or the Þle.

Link Enabled

400

The port has been enabled from the On-Line Port Operations menu.

Severity

Major (Level 2)

Advertising