Cabletron Systems SPECTRUM FRX6000 User Manual

Page 62

Advertising
background image

Configuring the Trap Table

3-12

Trap Messages

Duplicate of DLCI “n” on Port

428

Each connection sharing a DLCI must be on a different logical port, and two
records have been conÞgured in the FRX specifying the same logical port on one
DLCI. (DLCIs are conÞgured in records for logical ports, IP/LLC2/IPX interfaces
over frame relay, and frame relay PVCs.) Only one of the duplicate connections
will come up.

Severity

Minor (Level 3)

Action

Check the database records for the duplicate conÞguration and
change one (or more) of the records.

File Update: FRDLCI.DAT

429

The Frame Relay DLCI conÞguration Þle has been updated.

Severity

Informational (Level 4)

Received Port Disable Request

430

Self-explanatory.

Severity

Critical (Level 1)

Action

None; however, all users of this port should be made aware of the
disable.

Received Port Dump Request

431

The BSC device has experienced a problem that caused it to send a request to send
a dump to the port.

Severity

Critical (Level 1)

Action

Check the device.

Node Under Remote Control

432

Self-explanatory.

Severity

Informational (Level 4)

Remote Control Released

433

Self-explanatory.

Severity

Informational (Level 4)

Remote Control CXN Clr cc= “n” dc = “n”

434

A remote control connection was cleared.

Severity

Informational (Level 4)

Action

Depends on the cause.

Advertising