Cabletron Systems SPECTRUM FRX6000 User Manual

Page 63

Advertising
background image

Trap Messages

3-13

Configuring the Trap Table

LG Buffer MALLOC Problem PKTs Lost

435

This applies to a debug tool used by service personnel, and will not appear under
normal operation.

Severity

Major (Level 2)

RCV Unknown Event Code from Net.

436

An unknown event was received from the network.

Severity

Major (Level 2)

RCV Invalid Event Format from Net.

437

The node has received an event with an invalid format.

Severity

Informational (Level 4)

DOS Error Handler Exceeded Limit

438

The FRX was performing a DOS operation and, for some reason, could not reach
DOS.

Severity

Major (Level 2)

Action

Reboot the node and watch for error messages during boot-up. If
the problem persists, contact your service representative.

Database Error, Access Restricted

439

The database is inconsistent with what the software expects.

Severity

Critical (Level 1)

Action

Contact your service representative.

Abrev Addr File Upd: ABVSUB.DAT

440

The Abbreviated Address Þle has been updated.

Severity

Informational (Level 4)

Async Init File Upd: ASYSETUP.DAT

441

The Async Console Þle has been updated.

Severity

Informational (Level 4)

BSC Device File Upd: BSCDSP.DAT

442

The BSC Interactive Devices Þle has been updated.

Severity

Informational (Level 4)

LP Config File Upd: LPTYPE.DAT

443

The Line Processor conÞguration Þle has been updated.

Severity

Informational (Level 4)

Advertising
This manual is related to the following products: