Cabletron Systems SPECTRUM FRX6000 User Manual

Page 69

Advertising
background image

Trap Messages

3-19

Configuring the Trap Table

Alloc Error on Master SNMP Agent

494

A buffer could not be allocated to process an SNMP message.

Severity

Critical (Level 1)

BPAD: Invalid Q Pkt “n”—PL

500

An invalid Q packet has been received, disabling the port.

Severity

Minor (Level 3)

Action

ConÞgure the LIC or remove it from the node.

BPAD: Invalid Pkt “n”—PL

501

An invalid packet has been received, disabling the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

BPAD: Invalid MSG “n”—Link

502

An invalid message has been received, disabling the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

BPAD: Invalid MSG “n”—Exchange

503

An invalid message has been received, disabling the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

BPAD: Invalid CUA “n” DUA “n”

504

An invalid message has been received, disabling the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

LINK: Invalid MSG fc “n”—BPAD

505

An invalid message has been received, disabling the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

BSCI: Invalid control block

513

An error has occurred and has disabled the port.

Severity

Minor (Level 3)

Action

Take the same action as for message 500.

Advertising
This manual is related to the following products: