Cabletron Systems SPECTRUM FRX6000 User Manual

Page 92

Advertising
background image

Frame Relay Status and Configuration

5-4

Configuring Frame Relay Ports

Possible line speed entries are:

75

64000

512000

1008000

1472000

150

72000

560000

1024000

1512000

300

112000

576000

1064000

1536000

600

128000

616000

1088000

1568000

1200

168000

640000

1120000

1600000

2400

192000

672000

1152000

1624000

4800

224000

704000

1176000

1664000

9600

256000

728000

1216000

1668000

14400

280000

768000

1232000

1728000

19200

320000

784000

1280000

1792000

24000

336000

832000

1288000

1856000

28800

384000

840000

1344000

1920000

38400

392000

896000

1400000

1984000

48000

448000

952000

1408000

2048000

56000

504000

960000

1456000

If you enter a value that is within the valid range but not equal to one of the
values listed above, the speed will be rounded up. If an RS-232 DCE port is
directly connected to the DTE via the standard Cabletron cable, the maximum
supported speed is 64000. If longer cabling is used, the maximum speed is 19200.

N1 Polling Count

The Polling Count speciÞes the number of polling cycles that must pass between
requests for full status reports, which include the status of all PVCs conÞgured on
the physical link. At an interval speciÞed by the T1 Link Integrity Timer
(described below), the logical data terminal equipment (DTE, or user-side
equipment, typically a workstation or router) will send a status enquiry to its
attached DCE (or network-side equipment), requesting the status of the network
link. Each exchange of one enquiry and one response (or status message) deÞnes
one polling cycle. After the number of cycles speciÞed by this value, a request for
a full status report will be sent.

N2 Error Threshold

The error threshold deÞnes the number of link reliability and/or protocol errors
that can occur during the period deÞned by the N3 Monitored Events Count
(described below) before the logical DCE is declared inactive.

NOTE

If this port is conÞgured as the logical data communications equipment (DCE), status
enquiries will be initiated at its attached DTE (or user-side equipment), and the local node
will respond with status messages. You can determine which link partner is the logical
DTE and which is the logical DCE (network-side equipment) by checking the Logical
DCE

Þeld in this window (described below).