Cabletron Systems SPECTRUM FRX6000 User Manual

Page 166

Advertising
background image

BSC Interactive Configuration

8-10

Configuring BSCI Devices

Figure 8-3. BSCI Device Information

The top part of the window displays a list of conÞgured BSCI devices. The bottom
part of the window allows you to modify or add the following BSCI device
information:

Control Unit ID

This ID is a number 0 through 31 and identiÞes the control unit.

Device Unit ID

Enter a number, 0 through 31. Up to 32 Device Units can be conÞgured for each
Control Unit.

Connection ID

This number identiÞes the association between a local subscriber on a BSCI port
and a device conÞgured here in this table. It must match a Connection ID in the
BSCI Subscriber Information window (see

BSCI Subscriber ID Information

,

page 8-7

). Valid values are 0 through 255. The default value for this parameter is 0.

Single User VC (virtual circuit)

This read-only parameter speciÞes whether each end of the connection is within a
same or different Control Unit/Device Unit pair. This parameter is currently not
supported and is set to No.

Advertising
This manual is related to the following products: