Input configurations, Figure 1-10, Grnd-referenced source w/ diff input – ADLINK USB-1210 User Manual

Page 23: Figure 1-11, Floating source w/ diff input

Advertising
background image

Introduction

13

USB-1210

devices that plug into the existing power systems are
ground-referenced signal sources.

Input Configurations

Differential Input Mode

Differential input mode provides positive signal and negative
signal inputs that respond to signal voltage difference between
them, as shown. If the signal source is ground-referenced, dif-
ferential mode can be used for noise rejection for improvement
over single-ended mode.

Figure 1-10: GRND-Referenced Source w/ DIFF Input

Connection of a floating signal source to the USB-1210 module
in differential input mode is further shown. For floating signal
sources, the negative side of the signal should be connected to
the AIGND, with less noise coupled into the signal connections
than in single-end mode.

Figure 1-11: Floating Source w/ DIFF Input

AIxH

AIxL

x = 0, ..., 3

Ground
referenced
signal source

To A/D
converter

IGND

+

-

Instrumentation amplifier

V

cm

Common-mode
noise & Ground
potential

+

-

Input multiplexer

AIxH

AIxL

x = 0, ..., 3

+ To A/D

Converter

IGND

+

-

-

Instrumentation
Amplifier

Input Multiplexer

Floating
Signal
Source