Mode 8: continuous gated pulse generation, Mode 9: edge separation measurement, Figure 3-20 – ADLINK USB-1210 User Manual

Page 47: Mode 7-single-triggered continuous pulse, Figure 3-21, Mode 8-continuous gated pulse, Figure 3-21: mode 8-continuous gated pulse

Advertising
background image

Operation & Calibration

37

USB-1210

Figure 3-20: Mode 7-Single-Triggered Continuous Pulse

Mode 8: Continuous Gated Pulse Generation

This mode generates periodic pulses with programmable pulse
interval and pulse-width following software start. GPTC_GATE
enables/disables calculation. When GPTC_GATE is inactive, the
counter halts the current count value. Generation of two pulses
with a pulse delay of four and a pulse-width of three is shown.

Figure 3-21: Mode 8-Continuous Gated Pulse

Mode 9: Edge Separation Measurement

Measures the time differentiation between two different pulse sig-
nals. The first pulse signal is connected to GPTC_GATE and the
second signal is connected to GPTC_AUX. Clocks that pass
between the rising edge signal of two different pulses through the
80 MHz internal clock or external clock are calculated. You can
calculate the time period via the known clock frequency. The max-

4