18 power and ground – ADLINK cExpress-BL User Manual

Page 24

Advertising
background image

Page 24

cExpress-BL

Signal

Pin # Description

I/O

PU/PD

Comment

BATLOW#

A27

Battery low input. This signal may be driven low by external circuitry to
signal that the system battery is low, or may be used to signal some other
external power-management event.

I 3.3VSB

PU 10k
3.3VSB

LID#

LID button. Low active signal used by the ACPI operating system for a LID
switch.

I OD
3.3VSB

PU 10k
3.3VSB

Emulated
on GPIO
(BIOS)

SLEEP#

Sleep button. Low active signal used by the ACPI operating system to bring
the system to sleep state or to wake it up again.

I OD
3.3VSB

PU 10K
3.3VSB

Emulated
on GPIO
(BIOS)

3.3.18 Power and Ground

Signal

Pin #

Description

I/O

PU/PD

Comment

VCC_12V A104-A109

B104-B109

Primary power input: +12V nominal (5 ~ 20V wide input).
All available VCC_12V pins on the connector(s) shall be used.

P

5~20

V

VCC_5V_SBY

B84-B87

Standby power input: +5.0V nominal. If VCC5_SBY is used, all
available VCC_5V_SBY pins on the connector(s) shall be used.
Only used for standby and suspend functions. May be left
unconnected if these functions are not used in the system design.

P

5Vsb

±5%

VCC_RTC

A47

Real-time clock circuit-power input. Nominally +3.0V.

P

GND

A1, A11, A21, A31,
A41, A51, A57, A66,
A80, A90, A96,
A100, A110, B1,
B11, B21 ,B31, B41,
B51, B60, B70, B80,
B90, B100, B110

Ground - DC power and signal and AC signal return path.

P

Advertising