1 board specific sema functions, 1 voltages, 2 main current – ADLINK cExpress-BL User Manual

Page 38: 3 bmc status, Board specific sema functions, Main current = (msb_n<<8 + lsb_n) x 8.06ma

Advertising
background image

Page 38

cExpress-BL

5.1 Board Specific SEMA Functions

5.1.1

Voltages

The BMC of the cExpress-BL implements a voltage monitor and samples several onboard voltages. The voltages can be read by calling the
SEMA function “Get Voltages”. The function returns a 16-bit value divided into high-byte (MSB) and low-byte (LSB).

ADC Channel

Voltage Name

Voltage Formula [V]

0

+V1.5S

(MSB<<8 + LSB) x 3.3 / 1024

1

+VCORE

(MSB<<8 + LSB) x 3.3 / 1024

2

+V1.05S

(MSB<<8 + LSB) x 3.3 / 1024

3

+V3.3A

(MSB<<8 + LSB) x 1.100 x 3.3 / 1024

4

+VDDQ (V1.35 ~ V1.5)

(MSB<<8 + LSB) x 3.3 / 1024

5

+V5A_DUAL

(MSB<<8 + LSB) x 1.833 x 3.3 / 1024

6

+VIN

(MSB<<8 + LSB) x 6.000 x 3.3 / 1024

7

(MAIN CURRENT)

Use Main Current Function

5.1.2

Main Current

The BMC of the cExpress-BL implements a current monitor. The current can be read by calling the SEMA function “Get Main Current”. The

function returns four 16-bit values divided in high-byte (MSB) and low-byte (LSB). These 4 values represent the last 4 currents drawn by the

board. The values are sampled every 250ms. The order of the 4 values is NOT in chronological order. Access by the BMC may increase the
drawn current of the whole system. In this case, there are still 3 samples not influenced by the read access.

Main Current = (MSB_n<<8 + LSB_n) x 8.06mA

5.1.3

BMC Status

This register shows the status of BMC controlled signals on the cExpress-BL.

Status Bit

Signal

0 WDT_OUT

1 LVDS_VDDEN

2 LVDS_BKLTEN

3 BIOS_MODE

4 POSTWDT_DISn

5 SEL_BIOS

6 BIOS_DIS0n

7 BIOS_DIS1n