3 Outer dimensions and technical data

Nominal thermal output (NWL)

8 kW

Partial-load thermal output

2.4 kW

Space heating capacity

55 – 190 m³

Degree of efficiency

> 90%

CO content at NWL

<180 mg/Nm³

CO content at partial-load

155 mg/Nm³

Flue gas temperature at NWL

150 °C

Flue gas mass flow rate at NWL

4.4 g/s

Flue gas mass flow rate at partial-load

3.2 g/s

Holding capacity, full tank

26 kg / 40 l

Fuel

Pellets

Pellet consumption min./max

0.6 – 1.8 kg/h

Autonomy min./max

approx. 12 - 40 h

Air connector Ø

80 mm

Flue connector Ø

100 mm

Current upon switching on

300 W

Operating current

50 W

Voltage / current frequency

230 V / 50 Hz

Voltage fluctuations

0.9 - 1.1 of the rated voltage

Frequency fluctuations

0.99 - 1.01 of the rated frequency, constant

0.98 - 1.02 short-term

Dimensions

H x W x T

1100 x 526 x 498 mm

Weight

150 kg

Minimum spacing

side

150 mm

rear

100 mm

front

800 mm

Temperature limits

0 - 40°C

Relative humidity

non-condensing

Installation location

above sea level

< 1000 m