Austroflamm Polly User Manual

Page 49

Advertising
background image

Polly

47

english

To show the current ambient temperature, go through the menu by pressing the menu key for the menu

"Temperature". The current ambient temperature is then shown on the display.

To set the desired ambient temperature, in the "Temperature" menu press the Enter key. On the display,
the set target temperature is shown in the Edit mode (the value blinks). You can raise or lower this value

with the Edit keys. To complete, press the Enter key to confirm the set temperature. The current ambient

temperature is then shown on the display.

4.6 Setting the output level

The control unit regulates the fire chamber so that optimum output is ensured. You can override this

setting and reduce the burner output, thus saving fuel. The setting influences the fuel supply rate and
blower speed. The desired ambient temperature is more slowly attained this way, which can more quickly

lead to (glass pane) contamination.

The setting of the burner output pertains to the maximum burner output that the fire chamber generates to

heat the surrounding area. Once the set temperature has been attained, the burner output is

automatically cut back.

To show the current burner output, go through the menu by pressing the menu key for the menu "Power".
The current burner output is then shown on the display.


You can constrain the setting of the burner output to slowly heat up to the desired ambient temperature.
For this, press on the Enter key in the "Power" menu. On the display, the burner output is shown in the
Edit mode (the value blinks). Using the Edit keys, you can set this value to either Automatic (max. output),
4, 3, 2, or 1 (min. output). To complete, press the Enter key to confirm the set burner output. The current

burner output is then shown on the display.

4.7 Setting the weekly switching program

With the control unit you can set the weekly switching program and thus automate operation of the fire
chamber. Six different programs can be set, whereby a max. of three programs can be selected for each
weekday. The program determines the start and finish times, as well as the desired temperature.
To set a program, call up the menu "Time

"

by pressing the menu key. Then, press the Edit key to select

the entry "Weekly timer periods

"

. On the display, [ 3 ] is shown.

Press the Enter key to select

"

Program 1". On the display, [ P1 ] is shown. Press the Enter key again to switch to the Edit mode for

Program 1. The hour value of the starting time blinks. Set the desired hour for the starting time using the
edit keys. Then press the right menu key. The minute value of the starting time blinks. Set the desired

minutes for the starting time. Press the right menu key and set the desired end time. Then, press the right
menu key to set the desired ambient temperature for the selected time period. Confirm the program
settings by pressing the Enter key. Repeat the previous steps to set the other programs.

Example:

Program 1

Program 2

Program 3

Program 4

Program 5

Program 6

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

05:30 07:30

08:00 11:30 12:00 23:00 17:00 23:00 20:00 22:30 04:00 07:00

16 °C

18 °C

19 °C

18 °C

17 °C

15 °C


To designate the programs to weekdays, call up the menu "Time

"

by pressing the menu key. Then, press

the Edit key to select the entry "Weekly timer days

"

. On the display, [ 4 ] is shown.

Press the Enter

key to select "

Monday". On the display, [ d1 ] is shown. Press the Enter key again to switch to the Edit

mode for Monday. The value for the 1st program blinks. Set the desired program using the edit keys.
Then press the right menu key. The value for the 2nd program blinks. Set the desired program.

If you

don't want to use all of the program places, then set this to

[ OFF ]

with the minus key.

Confirm the program settings by pressing the Enter key. Repeat the previous steps to set the programs
for all weekdays.


Example:

englisch