6 Troubleshooting

The control panel conveys messages and warnings for alarms and errors that occur while using the

control unit. The display symbols indicate a problem. In case of an alarm, the symbols blink; in case of

errors, the symbols remain continuously illuminated. In the event of an alarm, the fire chamber is still
capable of functioning; in the event of an error, there is a severe functional malfunction of the fire

chamber and the service personnel must be informed.

Every alarm and error is assigned a code with which the problem can be identified. To display the code,

keep the Cancel key pressed. If no alarm/error code is available, "----" will be shown on the display.

Display Code

Cause

Solutions

A001

Low fuel level

Refill fuel level

----

No fuel

Refill fuel level

A003

Combustion chamber or flue is dirty

Check and empty the combustion chamber,

have the flue swept

A004

Battery is weak

Replace battery

See Item 5. Replacing the battery

----

Air quantity sensor is dirty

Remove air quantity sensor and blow away
dirt from measurement sensor

Air quantity sensor is defective

Replace air quantity sensor

----

The door combustion chamber door
is open,
the ash box is not in place,
grate does not close

Close the door to the combustion chamber,
put in ash box,
check for pellets between grate and burner
bowl, grate motor

E109

Tank lid not completely closed,
grate cannot close

Remove possibly stuck pellets

E001

Control panel error

Take note of the error code and contact the
service personnel

E004

Mainboard communications error

E101

Excessive temperature in the
combustion chamber

E107

Flame temperature sensor error
(TC2)

E108

Safety temperature delimiter error

E109

Tank lid pressure switch error

E110

Room sensor error (NTC1)

E112

Combustion chamber sensor excess
temperature

E115

General error


To acknowledge the error message, keep the ON/OFF key pressed until the symbol no longer lights up.

6.1 LED display on the control unit

The control unit has two LED displays that provide information on the control unit operation. The LED
signals are described in the table below: