24. INTRODUCTION

Your ducted evaporative air conditioner is engineered to meet the rigours of our harsh Australian
environment. Operated and maintained in accordance with this manual, it will provide you with years of
quiet, cool and environmentally friendly operation. Please take the time to read this manual.

The principal of your unit is to introduce fresh air, which is washed through the filter pads to provide cool
fresh air. The air is exhausted taking with it any heat in the home.

GENERAL INFORMATION

If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or it’s service agent.
The unit is suitable for operation on mains supply, water pressure min 100kPa , max 500kPa.

25. UNIT OPERATION

EXHAUST

It is essential for successful operation of evaporative air-conditioning that there are sufficient exhaust
openings in the area to be ventilated. Open doors and windows will usually provide this.

The minimum exhaust opening should be as per the table guide set out below. It is recommended that
ceiling vents or exhaust fans be used where there is any doubt about there being sufficient exhaust area
available. Ceiling exhaust fans or ceiling vents should have a capacity equivalent to that of the Evaporative
air conditioner.

MODEL

MINIMUM EXHAUST

AREA

Small

0.85 m²

Medium

1.19 m² to 1.48 m²

Large

2.02 m²