Tractor

Check Drive Belt

Check belt every 50 hours for damage or wear.
Replace worn belt. Belt is properly tensioned
when long span (2) moves about 1/2" (13 mm)
when pushed. If needed, loosen alternator bolts
(1) and adjust idler pulley.

Check Hydraulic Reservoir Breather

Check hydraulic reservoir breather every 50
hours. Ensure breather is not clogged. Remove
dust around breather as needed by blowing with
low-pressure air. When breather element
becomes clogged, remove and clean or replace.

Location

Task

Notes

TRACTOR

Check drive belt

Check hydraulic reservoir breather

Check fuel tank breather

Check cab air filter

Change transmission fluid and filter (initial)

TRENCHER

Lube attachment driveshaft u-joints

EPG