RT115 Tier 3- SERVICE

AS NEEDED

210

RT115 Tier 3 - SERVICE

AS NEEDED

Replace Saw Segments

Replace worn segments as needed.

To repair, clamp jig to block and weld block to the segment with
E7018 or equivalent.

NOTICE: Welding can damage electronics.

Welding currents can damage electronic components.
Always disconnect the ECU ground connection from the
frame, harness connections to the ECU, and other
electronic components prior to welding on machine or
attachments. Connect welder ground close to welding point
and make sure no electronic components are in the ground
path. We recommend that NO WELDING signs be
prominently displayed on machine.

Disconnect battery at battery disconnect switch before
welding to prevent damage to battery.

Do not turn off battery disconnect switch with engine
running, or alternator and other electronic devices may be
damaged.

Replace Saw Segments

Replace worn segments as needed.

To repair, clamp jig to block and weld block to the segment with
E7018 or equivalent.

NOTICE: Welding can damage electronics.

Welding currents can damage electronic components.
Always disconnect the ECU ground connection from the
frame, harness connections to the ECU, and other
electronic components prior to welding on machine or
attachments. Connect welder ground close to welding point
and make sure no electronic components are in the ground
path. We recommend that NO WELDING signs be
prominently displayed on machine.

Disconnect battery at battery disconnect switch before
welding to prevent damage to battery.

Do not turn off battery disconnect switch with engine
running, or alternator and other electronic devices may be
damaged.

Advertising