10 Hour

Check Water Separators and Fuel
Filter

Check water separators and fuel filter every 10
hours. Drain at plug as needed until water is
removed and fuel runs from drain.

Check Hydraulic Fluid

With frame level, check fluid at sight glass every
10 hours. (Remove cover to see sight glass.) Add
THF at fill as necessary. Fluid capacity up to
sight glass is 24 gal (91 L).

Clean dust from cap by blowing with low-pressure
air.

IMPORTANT:

Open cap slowly, tank may be under
pressure. Fill cap includes a 3 psi check
valve.

Do not open unless adding hydraulic fluid.