Service - 165

Tier 3 Engine

Operator Alert Indicator

When a non-critical engine fault occurs, the operator alert indicator on the
gauge cluster will light. A fault code will be stored in the diagnostic gauge.

Engine Shutdown Indicator

When an critical engine fault occurs, the engine shutdown indicator will
light. A fault code will be stored in the diagnostic gauge, and the engine will
shut down within 30 seconds.

Tachometer/Hourmeter/Diagnostic Gauge

To display codes:

1.

Press the selection switch to scroll through the gauge parameters until
FMI SPN code is displayed.

2.

Press the selection switch to scroll through all codes.

To clear active codes:

1.

Turn ignition switch to STOP.

2.

Turn ignition switch back to START.

To change display options:

1.

Turn the ignition switch to STOP.

2.

Press and hold the selection switch.

3.

Turn the ignition switch to ON.

4.

Press and hold the selection switch to scroll through display options.

5.

Release the switch to stop scrolling.

6.

To turn options off or on, press the selection switch twice.

7.

To save changes, continue scrolling until EXIT CFG is displayed, then press and hold.