Dunkirk DWB Series User Manual

Page 27

Advertising
background image

10.5 Indicator During Operation

Heating
Call for heat (generated by Room Thermostat) is indicated

by hot air fl ashing above radiator symbol on the control.

Hot water
Call for hot water (generated by drawing off hot tap water) is

indicated by hot water fl ashing under the tap on the control.

10.6 Turning on and off

NO electrical power to the boiler

The antifreeze system does not work when power and/or

gas to the unit are turned off. To avoid damage caused by

freezing during long idle periods in winter, it is advisable to

drain all water from the boiler, DHW circuit and system; or

drain just the DHW circuit and add a suitable antifreeze to

the heating system. See Section 5.2 page 11.

10 - OPERATING INSTRUCTIONS

10.3 Checks During Operation

• Check for leaks in piping systems. Correct immediately

if found.

• Check the effi ciency of the fl ue gases and combustion

air ducts while the boiler is working.

• Check water is circulating between boiler and systems.
• Verify the gas valve modulates correctly in both

heating and hot water production phases.

• Check proper ignition of the boiler by turning it on and

off with the room thermostat.

• Verify with no call for heating burner correctly ignites

on opening hot water tap. Check that during heating

operation, on opening hot water tap, heating circulator

stops and there is regular production of hot water.

• Check parameters are programmed correctly and

perform any required customization (compensation

curve, power, temperatures, etc.)

10.4 Control Panel

64

2

1

7

4

3

11

10

12

6

8

15

13

14

5

9

Key

1 = DHW temperature setting decrease button
2 = DHW temperature setting increase button
3 = Heating system temperature setting decrease button - CH
4 = Heating system temperature setting increase button - CH
5 = Display
6 = Summer/Winter mode selection - Reset button
7 = Unit On/Off - Economy/Comfort mode selection button
8 = DHW symbol
9 = DHW mode
10 = Summer mode
11 = Multifunction - Temperature
12 = Eco (Economy) mode
13 = Heating
14 = Heating symbol
15 = Burner On and actual power
64 =

C.H. temperature pressure gauges

27

Advertising