Dunkirk DWB Series User Manual

Page 28

Advertising
background image

Boiler Ignition

Supply unit with electricity.

Boiler ignition

For 120 seconds display will show FH which identifi es the

air venting cycle for the heating system.

During the fi rst 5 seconds the display will show the

software release of the card also.

Open the gas valve before the boiler.

When FH vanishes, boiler is ready to automatically work

whenever hot tap water is drawn or room thermostat

requests heating.

Turning the boiler off

Press the button below (see item 7 on the control panel

display) for 5 seconds.

When the boiler is turned off, the electronic board is still

powered.

Domestic hot water and heating operation are disabled. The

antifreeze system remains activated.

To re-light the boiler, press the button (see item 7 on the

control panel display) again for 5 seconds.

Boiler will be immediately ready to operate whenever

domestic hot water is drawn or room thermostat demand.

Summer/Winter Switchover

Press the button for 2 seconds.

Display will activate Summer symbol (see item 10 on the

control panel display). Boiler will deliver tap water only.

Antifreeze system stays on.

To turn off Summer mode, press button again for 2

seconds.

Heating temperature setting

Use heating buttons (see items 3 and 4 on the control

panel display) to change the temperature from minimum of

86°F (30C) to a maximum of 185°F (85C); it is advisable to

not operate boiler below 113°F (45C).

Domestic hot water temperature adjustment

Operate DHW buttons (see items 1 and 2 on the control

panel display) to vary the temperature from a minimum of

50°F (40C) to a maximum of 149°F (55C)

10 - OPERATING INSTRUCTIONS

28

Advertising