Unvtcontrolcfg – Echelon Lumewave CPD 3000 Lighting Controller User Manual

Page 15

Advertising
background image

CPD 3000 Integration Guide

15

nciPowerProfile UNVTpowerProfile

Defines the nominal power

measured at 5 commanded
nviLampValues

0.5%, 25%,

50%, 75%, 100%) while driving
the driver/lamp combination.

This CP must be set for

lowPower/HighPower, and
measured with nvoLampFb
values to work correctly. They
will depend on the minPWM and
maxPWM

fields defined in the

following section.

UNVTControlCfg

This section describes how the fields in this configuration property are applied in the
LC.

Figure 5

. UNVTcontrolConfig Field Details

Field

Type

Notes

defaultLev SNVT_lev_cont

This is the initial value before an update
to nviLampValue is received by the LC to
drive the lamp value at power ON or reset.

The default value is 100%. This value only

applies after the CPD 3000 is commission
by the SmartServer. When unconfigured,

the CPD 3000 will turn ON the controlled

light to full ON. When power is applied to
the OLC, the application enforces a 10s
minimum time (even if CoolDownTm =0)
before applying this value. A non-zero