Wiring specification and diagram, Us model, European model – Echelon Lumewave CPD 3000 Lighting Controller User Manual

Page 7

Advertising
background image

CPD 3000 Integration Guide

7

Wiring Specification and Diagram

Here are the wiring specifications and diagram for US and European models of the

CPD 3000. The CPD 3000 is not suitable for installing above 15,000 feet altitude.
The controller must be installed in the light fixture, inside a street light pole, or in a

street light cabinet. The CPD 3000 is not intended to be installed in an open

outdoor environment.

US Model


Three AWG 16 wires for AC mains input:

Black Line

In

White

Neutral In or Line 2 In*

Green Ground

*

May be powered Line-to-Line if Line-to-Line Voltage is 100-277 VAC and all CPD 3000s, and the

segment controller, are connected to the same circuit pair.

Three AWG 22 wires for control of signal ouput (IEC60929)


Blue

10V signal for PWM control

Black Ground
Violet

Signal for 0-10V control


European Model


Three AWG 16 wires for AC mains input:


Brown Line

In

Blue

Neutral In or Line 2 In*

Green/Yellow Ground


*

May be powered Line-to-Line if Line-to-Line Voltage is 100-277 VAC and all CPD 3000s, and the

segment controller, are connected to the same circuit pair.


Three AWG 22 wires for control of signal ouput (IEC60929)


Blue

10V signal for PWM control

Black

+ Signal for 0-10V control

White

- Signal for 0-10V control