17

6.0 Replacement Parts

ENMET

replacement part numbers:

Description of Part

Part Number

Sensor PID

03028-000

Calibration Regulator, for 17 liter, cylinder

03700-500

Zero Gas, 20.9% O2, 17 liter

03296-209

Sampling Regulator w/hose, quick disconnect

03412-003

Sampling Hose w/quick disconnect

03412-004

Horn

62013-007

Calibration Gas, Consult

ENMET

Distributor or

ENMET

Corp.

7.0 Technical Data and Specifications

15 Amp fused branch circuit
100-240

V

AC

0.45A, 50/60 Hz

Electrical Power

0.6A, 24

V

DC

Temperature:

-20

°

to +60

°

C (-4

°

to +140

°

F)

preferred

0

°

to +20

°

C (32

°

to 68

°

F)

Relative Humidity

10-99% RH, non-condensing

Atmospheric Pressure

20 to 36 inHg (68 to 133 kPa)

Storage and Transport

Temperature:

0

°

to +40

°

C (32

°

to +104

°

F)

Relative Humidity

10-99% RH, non-condensing

Atmospheric Pressure

20 to 36 inHg (68 to 133 kPa)

Operation

Dimensions:

7.1 x 5.1 x 3 in(180x130x75mm)

Weight:

2 lbs (0.9 kg)

Material:

Polycarbonate

Strain relief:

3-6.5mm OD

Mechanical

Relays:

SPDT
Resistive Load

Inductive Load

10A at 110 V

AC

7.5A at 110 V

AC

10A at 30 V

DC

5A at 30 V

DC

Analog:

4-20mA

Digital:

RS-485-modbus

Audio:

105 dB at 30cm/12in

Outputs

N

OTE

:

All specifications stated in this manual may change without notice.