DIAGNOSTIC SERVICE MANUAL

DOMETIC® RM7030/RM7732

Refrigerators

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

4. When operating in the AES mode, the AES mode

indicator lamp "B" will illuminate. The control system

will automatically select between AC and GAS

operation with AC having priority over GAS. Either

the AC indicator lamp "A" or the GAS indicator lamp

"C" will illuminate depending on the energy source

selected by the control system. If the control system

is operating with AC energy and it then becomes

unavailable, the system will automatically switch to

GAS. As soon as AC becomes available again, the

control will switch back to AC regardless of the

status of GAS operation.

GAS MODE

1. Move the AES mode selector button (2) to the UP

position. The GAS mode indicator lamp "C will

illuminate. After 45 seconds the burner should be

ignited and operating normally.

2. On the initial refrigerator start-up, it may take longer

than 45 seconds to allow air to be purged from the

gas line. If the gas does not ignite within 45 seconds,

the CHECK indicator lamp "D" will illuminate and the

GAS mode indicator lamp "C" will go off. To reset

when the CHECK indicator lamp "D" is illuminated,

press the main power ON/OFF button (1) to the OFF

then ON position.

If the control is switched to AC operation while

the CHECK indicator lamp is on, it will function

properly, but the CHECK indicator lamp will not go

off until the main power ON/OFF button is pressed to

the OFF then ON position.

NOTE: Do not continue to reset GAS operation if

the CHECK indicator lamp continues to be illumi-

nated after several tries. If repeated attempts fail to

start the LP gas operation, check to make sure that

the LP gas supply tanks are not empty and all

manual shutoff valves in the lines are open.

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

THERMOSTAT

The thermostat on the refrigerator controls both the gas

and electric operation, thereby eliminating the necessity

of resetting each time a different energy source is

employed.
After the initial start-up, the thermostat should be moved

from "COLDEST" to the desired temperature setting,

usually about mid-setting.

STANDBY MODE OF OPERATION

This control system contains a feature where it will

continue to operate the cooling system in the event of a

failure of a major operating component. Two different

modes of operation can occur in this category.

If for some reason the display module becomes non-

functional, the control system will revert to fully auto-

matic operation – selecting the best energy source

available with AC and GAS priority. The temperature of

the refrigerator will be maintained at the MID position

within normal temperature tolerances. The power

module will continually attempt to reestablish operation

of the display module.

The second standby mode of operation will execute

when a failure of the temperature sensing device or

associated electronic circuitry occurs. If this should

occur, the control system will operate on the energy

source selected via the control panel. The cooling unit

will run continuously on the selected energy source. The

refrigerator will continue to operate in this mode indefi-

nitely or until a new sensor is installed and the system is

reset.

1.3 RM7732 REFRIGERATOR OPERATION

A

C

D

E

2-WAY DISPLAY PANEL

B

AUTO MODE

Press the AUTO mode selector button (2) to the DOWN

position. If 120 volts AC is available, the AC mode

indicator lamp (A) will illuminate indicating AC operation.

If 120 volts AC is not available, the GAS mode indicator

lamp (C) will illuminate and the control system will

automatically switch to GAS operation.

If the CHECK indicator lamp (D) illuminates and the

GAS mode indicator lamp (C) is OFF, the controls have

failed to ignite the burner in the GAS mode. GAS

operation may be reset by pressing the main power ON/

OFF button (1) to the OFF then ON position. (See GAS

MODE.

Press the TEMPERATURE SELECTOR button (3) until

the lamp at the desired position is illuminated.