Description of operating modes – Dometic RM7732 User Manual

Page 11

Advertising
background image

8

DOMETIC® RM7030/RM7732

Refrigerators

DIAGNOSTIC SERVICE MANUAL

GAS MODE

Move the AUTO mode selector button (2) to the UP

position. The GAS mode indicator lamp (C) will illumi-

nate. After 45 seconds the burner should be ignited and

operating normally.

On the initial refrigerator start-up, it may take longer

than 45 seconds to allow air to be purged from the gas

line. If the gas does not ignite within 45 seconds, the

CHECK indicator lamp (D) will illuminate and the GAS

mode indicator lamp (C) will go off. To reset when the

CHECK indicator lamp (D) is illuminated, press main

power ON/OFF button (1) to the OFF then ON position.

NOTE: DO NOT continue to reset GAS operation if

the CHECK indicator lamp continues to be illumi-

nated after several tries.

Press the TEMPERATURE SELECTOR button (3) until

the lamp (E) at the desired position is illuminated.

THERMOSTAT

The thermostat on the refrigerator controls both the gas

and electric operation, thereby eliminating the necessity

of resetting each time a different energy source is

employed.

After the initial start-up, the thermostat should be moved

from "COLDEST" to the desired temperature setting is

usually about mid-setting.

TO SHUT OFF THE REFRIGERATOR

The refrigerator may be shut off while in any mode of

operation by pressing the main power ON/OFF button

(1) to the UP (OFF) position. This shuts off all DC power

to the refrigerator, including the interior light.

DESCRIPTION OF OPERATING
MODES

AUTO MODE

When operating in the AUTO mode, the AUTO mode

indicator lamp (B) will illuminate. The control system will

automatically select between AC and GAS operation

with AC having priority over GAS. Either the AC indica-

tor lamp (A) or the GAS indicator lamp (C) will illuminate

depending on the energy source selected by the control

system. If the control system is operating with AC

energy and it then becomes unavailable, the system will

automatically switch to GAS. As soon as AC becomes

available again, the control will switch back to AC

regardless of the status of GAS operation.

GAS MODE

When operating in the GAS mode, the AUTO mode

indicator lamp (B) will be off and the GAS mode indica-

tor lamp (C) will be illuminated. This mode provides LP

gas operation only. The control system will activate the

ignition system and will attempt to light the burner for a

period of approximately 45 seconds. If unsuccessful,

the CHECK indicator lamp (D) will illuminate and the

GAS mode indicator lamp (C) will turn off.

To restart GAS operation, press the main power ON/

OFF button (1) to the OFF and then ON position. The

control system will attempt a new 45 second ignition

sequence.

If the refrigerator has not been used for a long time or

the LP tanks have just been refilled, air may be trapped

in the supply lines. To purge the air from the lines may

require resetting the main power ON/OFF button (1)

three or four times. If repeated attempts fail to start the

LP gas operation, check to make sure that the LP gas

supply tanks are not empty and all manual shutoff

valves in the lines are open.

If the control is switched to AC or DC operation while

the CHECK indicator lamp is on, it will function properly,

but the CHECK indicator lamp will not go off until the

main power ON/OFF button is pressed to the OFF then

ON position.

STANDBY MODE OF OPERATION

This control system contains a feature where it will

continue to operate the cooling system in the event of a

failure of a major operating component. Two different

modes of operation can occur in this category.

If for some reason the display module becomes non-

functional, the control system will revert to full automatic

operation selecting the best energy source available

with AC as first priority, and GAS as the second priority.

The temperature of the refrigerator will be maintained at

the MID position within normal temperature tolerances.

The power module will continually attempt to reestablish

operation of the display module.

The second standby mode of operation will execute

when a failure of the temperature sensing device or

associated electronic circuitry occurs. If this should

occur, the control system will operate on the energy

source selected via the control panel. The cooling unit

will run continuously on the selected energy source. The

refrigerator will continue to operate in this mode indefi-

nitely or until a new sensor is installed and the system is

reset.

Advertising