10 door switch – Dometic RM7732 User Manual

Page 20

Advertising
background image

17

DIAGNOSTIC SERVICE MANUAL

DOMETIC® RM7030/RM7732

Refrigerators

Check for voltage at the heating element connection

terminals J7 and J8 on the circuit board. If no

voltage is present, check the 5 amp AC and 3 amp

DC fuses. If fuse is defective, replace the fuse. If

fuses are good, replace the circuit board.

G. GAS MODE: NOTE: The PAL tester will allow for

proper testing of the integrity of the upper and lower

circuit boards. PAL is available from your Dometic

parts distributor.
ALL TESTS ARE TO BE DONE WITH THE REFRIG-

ERATOR IN THE COOLING MODE.
Before checking the circuit board for gas operation,

verify that the following components are good: Upper

Circuit Board, Thermistor and 3 Amp Fuse.

NOTE: Each of the following tests should be

done according to pin locations. The wire colors

may vary.
First, check for voltage during trial-for-ignition

(approximately 45 seconds) at Plug 3, Terminals 1

(white wire) and 2 (yellow wire) to the solenoid. If no

voltage is present, change the circuit board. If

voltage is present, check for voltage at the solenoid.

If voltage is not present, check the wires and con-

nections.
Next, check for voltage to the igniter. If no voltage is

present, check the wires. If good, then change the

circuit board. If voltage is present, this portion of the

board is good.
NOTE: When millivolts to the lower circuit board are

10 ± 3, the power to Plug 3, Terminal 4 (blue wire)

will be shut off. If flame extinguishes during the

cooling mode, the circuit board will not supply

voltage to Plug 3, Terminal 4 (blue wire) again until

the millivolts have decreased to 10±3. This process

could take up to 15 seconds or longer.

To check the flame sense circuit of the lower circuit

board, operate the refrigerator on GAS mode, then

measure the millivolts between J3 terminal and the

other wire connection from the thermocouple. The

millivolt meter should read between 25 to 35 milli-

volts with the gas flame burning. Next, turn the

manual shutoff valve to OFF and watch the millivolt

reading as it drops. Note the millivolt reading when

Plug 3, terminal 4 (blue wire) receives power. It

should be 10±3 millivolts or 7 to 13.

Repeat this test several times. If the igniter fails to

spark on any test sequence, it should be replaced.

If the millivolt readings vary more than 1 to 2 MV

from one test to the other when power is supplied to

Plug 3, terminal 4, replace the lower circuit board.

NOTE: Verify all connections are clean and tight

before replacing either component.

5.10 DOOR SWITCH

The door switch is an open switch when the switch arm

is depressed (interior light should be off). When the

refrigerator door is open the switch is closed (interior

light should be on). Check that the switch assembly is

properly aligned and that it is not broken. Check the

switch assembly for continuity.

NOTE: To do a continuity check, first be sure all power

is disconnected or OFF to the refrigerator. Second,

remove all wires from the switch assembly, then check

the switch. After the check, be sure the switch assem-

bly is wired properly per the wiring diagram.
When the switch arm is depressed, there should not be

continuity. When the switch arm is NOT depressed,

there should be continuity. If any of these checks are

incorrect, replace the switch.

P1

P2

P3

J1 J2 J3 J4 J5 J6 J7 J8

J10

3 AMP FUSE

FIVE
AMP
FUSE

Black 3

Open 2

Green 1

6 Brown

5 Red

Open 3
Blue 4

1 White

1 White

2 Yellow

4 Orange

or White

4 Orange

or White

Advertising