Dometic RM7732 User Manual

Page 19

Advertising
background image

16

DOMETIC® RM7030/RM7732

Refrigerators

DIAGNOSTIC SERVICE MANUAL

C. GAS OPERATION

THESE PROCEDURES MUST BE FOLLOWED IN

SEQUENCE AND AT THE PROPER TERMINALS OR

DAMAGE TO THE BOARD WILL RESULT.

Before you check the circuit board for gas operation,

verify these components are good:

Igniter (Sec 5.5A)

High Voltage Cable (Sec. 5.6A)

Electrode (Sec. 5.11)

Solenoid (Sec. 5.4A)

Upper Circuit Board (Sec. 5.8A to 5.8I)

Thermostat (Sec. 5.1)

Also be sure NO voltage is present at the

IGN lock terminal, and delay mode is not

activated. First, check that voltage in

excess of 10.5 volts is between the yellow

terminal on the 6-pin connector (positive

[+] lead from meter) to the ground strip

(negative [–] lead from meter). If less than

10.5 volts, correct wiring and/or power

source problem.

Next, check for the pulse voltage from the igniter at

the orange terminal on the 6-pin connector (negative

[–] lead from meter) and the ground strip (positive [+]

lead from meter). If there is no signal voltage, check

the igniter (see Sec. 5.5A) and the orange wire and

connections. If signal voltage is present, next check

YELLOW

6 Pin

ORANGE

6 Pin

for voltage on the solenoid wires at the

circuit board. Positive lead from meter to

the gray wire and negative lead from the

meter to the black wire. If voltage is 9.5

volts or more, the circuit board is good. Do

not replace. If no voltage is present, replace

the circuit board.

D. DC VOLTS TO UPPER CIRCUIT BOARD

THESE PROCEDURES MUST BE FOLLOWED IN

SEQUENCE AND AT THE PROPER TERMINALS OR

DAMAGE TO THE BOARD WILL RESULT.

This check is to determine if the

lower circuit board is providing

voltage to the upper circuit board.

Measure between the brown

terminal on the 10-pin connector

(positive [+] lead from meter) to

the blue terminal on the 7-pin

connector (negative [–] lead from

meter). A voltage reading indi-

cates the circuit board is good. If

no voltage is present, replace the circuit board.

NOTE: Before changing the circuit board, be sure all

troubleshooting steps have been followed.

BROWN

BLUE

10 Pin

7 Pin

RM7030 (Product No. 921890401) & RM7732

E. DC VOLT: ALL TESTS ARE TO BE DONE WITH

THE REFRIGERATOR IN THE COOLING MODE.

Before any checks are made, make sure the board

is receiving proper DC volts. Measure volts between

terminal J4 and the ground strip. Voltage should be

the same as at the positive (+) and negative (-) on

the terminal block. If not, check for loose connec-

tions.

F. AC MODE: NOTE: The PAL tester will allow for

proper testing of the integrity of the upper and lower

circuit boards. PAL is available from your Dometic

parts distributor.
ALL TESTS ARE TO BE DONE WITH THE REFRIG-

ERATOR IN THE COOLING MODE.
For AC heating element operation, check that

incoming AC voltage is present at terminals J5 and

J6 on the circuit board. If voltage is below 100 volts,

see Sec. 2.

B. AC OPERATION

THESE PROCEDURES MUST BE FOLLOWED IN

SEQUENCE AND AT THE PROPER TERMINALS

OR DAMAGE TO THE BOARD WILL RESULT.

For AC heating element operation, check that voltage is

present between the large black and large white wire at

the circuit board. If voltage is below 100 volts, the circuit

board will select another mode. If voltage is above 100

volts, check that AC volts are present at the heating

element connection. If no voltage is present, change the

circuit board.
NOTE: Before installing a new circuit board, correct the

cause of the failure, most likely it is the heating ele-

ments or wiring.

If voltage is present, DO NOT CHANGE THE CIRCUIT

BOARD. Check the following components: heating

elements, upper circuit board, thermostat and wiring.

Advertising
This manual is related to the following products: