2 rm7030 (prod. #921890401) refrigerator operation – Dometic RM7732 User Manual

Page 9

Advertising
background image

6

DOMETIC® RM7030/RM7732

Refrigerators

DIAGNOSTIC SERVICE MANUAL

FLAME FAILURE DURING LP GAS

OPERATION

If the LP gas flame fails during the burner cycle, the

high voltage spark will continue arcing for up to three

minutes.

At the end of three minutes the gas control will stop the

flow of LP gas to the burner, the sparking will stop and

the red indicator lamp "H" will light up. LP gas operation

will not be possible as long as this indicator is ON.

To restart LP gas operation, turn the main system

switch "C" to "OFF" for five seconds and then back ON.

This will reset the AES controls and turn off the flame

failure indicator "H". The system will start another cycle

for gas ignition.

If the refrigerator has not been used for a long time or

the LP tanks have just been refilled, air may be trapped

in the supply lines. To purge the air from the lines may

require resetting (turning OFF and ON) the On/Off

switch "C" three or four times.

If repeated attempts fail to start the LP gas operation,

check to make sure that the LP gas supply tanks are

not empty and all manual Shutoff valves in the lines are

open.

NOTE: If you are in the AES mode when the flame

failure light "H" comes on, the mode indicator lamp "A"

(green light) will go out. If 120 volt AC power becomes

available during this period, the mode indication lamp

will come on showing that the refrigerator is operating

on another energy source. The red lamp "H" will remain

on until the AES system is reset with an OFF/ON

operation of the main switch "C". If you have selected

the LP gas only mode (control button "B"), the 120 volt

function has been locked out. If the burner fails to light,

the green lamp over button "B" will go out and the red

lamp "H" will glow indicating flame failure. Even if 120

volts is available, the refrigerator cannot switch to

electric operation and all cooling will stop. This fact must

be considered when selecting "gas only" operation.

120 VOLTS AC OPERATION

Since 120 volt AC is usually the most economical

source for operation of the refrigerator, the AES control

system is designed to select this mode whenever it is

available. The only exception to this is when push-

button "B" (LP gas only mode) is selected. The 120 volt

heating elements attached to the boiler provide the heat

necessary to operate the cooling system. The thermo-

stat controls the power ON and OFF to the elements

and maintains the desired temperature.

LOW VOLTAGE MONITOR

The AES system requires 12 volts DC power at all times

to operate properly. The DC power must be 9.5 volts

DC or higher. If the DC voltage drops below 9.5 volts

DC, the AES system will switch to an emergency

cooling mode.

1. The mode indicator lamp will go off (green light);

2. The system will revert to continuous LP gas

operation, with no thermostat control.

The refrigerator will continue to operate in the emer-

gency mode until the DC power supply is increased to

10.5 volts DC. When 10.5 volts is reached, the mode

indicator light (green) will come back on and normal

operation will resume.

During the low voltage condition, the interior light will

operate normally.

THERMOSTAT

The refrigerator is equipped with a thermostat that can

be adjusted to maintain various temperatures. Turn the

knob clockwise toward "MAX" for a lower temperature

and for a warmer temperature – turn the knob counter-

clockwise toward "MIN". Set the thermostat approxi-

mately mid-range and adjust it toward "MIN" or MAX" to

obtain the desired cabinet temperatures. Remember, at

the "MAX" setting, the heating element/burner is running

continuously and the lower cabinet temperatures are

obtained.

1.2 RM7030 (Product No. 921890401)

AES MODE

1. Move the AES mode selector button (2) to the

DOWN position. If 120 volts AC is available, the AC

mode indicator lamp "A" will illuminate indicating AC

operation. If 120 volts AC is not available, the GAS

mode indicator lamp "C" will illuminate and the

control system will automatically switch to GAS

operation.

2. If the CHECK indicator lamp "D" illuminates and the

GAS mode indicator lamp "C" is off, the controls

have failed to ignite the burner in the GAS mode.

GAS operation may be reset by pressing main power

ON/OFF button (1) to the OFF then ON position.

AES DISPLAY PANEL