AES FULLY AUTOMATIC MODE

Turn switch "C" to the "ON" position. The bulb above

push-button "A" will light up green, indicating that the

control system is in the fully automatic mode. In this

mode, 120 volts AC operation has first priority, meaning

the refrigerator will operate on 120 volts AC whenever it

is available. If 120 volts AC is not available, the system

will automatically switch to LP gas operation. The

thermostat inside the refrigerator cabinet cycles the

element/burner as required to maintain the desired

temperature.

NOTE: The AES controls will automatically go to the

fully automatic mode each time switch "C" is turned

"ON".

LP GAS OPERATION

When there is no electrical power available (120 volts

AC) or if the indicator lamp above button "B" is ON, the

AES system will switch to LP gas operation. When the

thermostat in the refrigerator cabinet calls for cooling,

the following sequence takes place:

A. A high voltage spark is created above the burner.

B. Power is sent to a solenoid which opens the gas

control, allowing LP gas to flow to the burner. The

spark ignites the LP gas and the small flame pro-

vides heat for the boiler.

C. The electrode mounted above the burner tube

monitors the flame continuously. If the flame should

fail for any reason, the high voltage spark will start

immediately and relight the flame.

When the thermostat reaches the desired temperature,

it will shut off the gas flame completely. The system will

remain on standby until cooling is again required.

LP GAS ONLY OPERATION

Turn switch "C" to the "ON" position and press push-

button "B". The green indicator lamp over push-button

"B" will come on and the refrigerator will operate only on

LP gas even if 120 volts are available. When the vehicle

engine is turned "OFF", the AES system initiates a 25

minute delay, preventing the refrigerator from operating

on LP gas.

LP GAS DELAY MODE

When the vehicle engine is turned off, the AES system

initiates a delay cycle which prevents the refrigerator

from operating on LP gas for 25 minutes. The purpose

of the delay is to avoid having a gas flame burning dur-

ing a refueling stop at a gas station (see WARNING).
If the vehicle engine is restarted during this delay pe-

riod, the LP gas operation will not start until the delay

period is over. This means each time the vehicle engine

is stopped, the complete 25 minute delay cycle will take

place. If 120 volt AC becomes available during this de-

lay cycle, the AES system will start operation in the 120

volt AC mode immediately, unless the push-button "B"

(LP gas only) has been pressed.
If the RV is stopped somewhere other than a gas sta-

tion, you may wish to cancel the delay cycle. To do this,

turn the main system switch to "OFF" for several sec-

onds, then turn the main system switch back to "ON"

and the system will immediately start operation in the

LP gas mode.

Most LP gas appliances used in recreational ve-

hicles are vented to the outside of the vehicle. When

parked close to a gasoline pump, it is possible that

the gasoline fumes could enter this type of appli-

ance and ignite from the burner flame, CAUSING A

FIRE OR AN EXPLOSION.
FOR YOUR SAFETY, it is recommended that all LP

gas appliances which are vented to the outside

should be shut off when refueling.
The AES system is designed to turn off the LP flame

during refueling stops by the use of the delay cycle

explained previously. However, you must remember

that the delay cycle will be activated only if the

refrigerator is properly connected to the vehicle

engine electrical circuit.
If the refrigerator is not connected to the engine by

the ignition lock wiring, the refrigerator must be

shut off during refueling. To do this, turn the main

system switch "C" to "OFF". Only after the vehicle

has been moved away from the refueling area

should the main system switch "C" be turned back

ON.

SECTION 1

1.1 OPERATION

RM7030 (Product No. 921890201 & 921890301)

OFF

ON

AC

A

B

C

D

E

F G

H

Advertising