DIAGNOSTIC SERVICE MANUAL

DOMETIC® RM7030/RM7732

Refrigerators

B. AES FUNCTION SWITCH

NOTE: The following checks should be made on the

upper circuit board and harness assembly BEFORE

replacing the upper circuit board or wiring harness.

The checks are to be done with the wiring harness

REMOVED from the lower circuit board, and the ON-

OFF switch turned to "ON".

With the AES function switch manually

depressed:

CONTINUITY should be indicated

between the blue terminal and the

black terminal on the 7-pin connector.

With the AES function switch NOT

depressed:

NO continuity should be indicated

between the blue and black terminals

on the 7-pin connector.
NOTE: If the check on AES function switch is not

correct, verify the wire harness has continuity. If wire

harness is good, replace the upper circuit board.

C. AES FUNCTION LAMP

NOTE: The following checks should be made on the

upper circuit board and harness assembly BEFORE

replacing the upper circuit board or wiring harness.

These checks are to be done with the wiring harness

REMOVED from the lower circuit

board and the ON–OFF switch

turned to "ON".

Measure resistance between the

brown terminal on the 7-pin

connector (positive [+] lead from

meter) to the brown terminal on

the 10-pin connector (negative

[–] lead from meter). The proper resistance is

approximately 26,000 ohms.

NOTE: If the check on the AES function lamp is not

correct, verify the wire harness has continuity. If wire

harness is good, replace the upper circuit board.

D.

GAS FUNCTION SWITCH

NOTE: The following checks should be made on the

upper circuit board and harness assembly BEFORE

replacing the upper circuit board or wiring harness.

The checks are to be done with the wiring harness

REMOVED from the lower circuit board and the ON-

OFF switch turned to "ON".

BROWN

BROWN

10 Pin

7 Pin

BLACK

BLUE

7 Pin

With the gas function switch

manually depressed: CONTI-

NUITY should be indicated

between the violet terminal on

the 10-pin connector to the

blue terminal on the 7-pin

connector. With the gas

function switch NOT de-

pressed:

A reading would NOT be indicated.

NOTE: If the check on gas function switch is not

correct, verify the wire harness has continuity. If wire

harness is good, replace the upper circuit board.

E. GAS FUNCTION LAMP

NOTE: The following checks should be made on the

upper circuit board and harness assembly BEFORE

replacing the upper circuit board or wiring harness.

These checks are to be done with the wiring harness

REMOVED from the lower

circuit board, and the ON–OFF

switch turned to "ON".
Measure resistance between the

brown terminal on the 10-pin

connector (negative [–] lead

from meter) to the white terminal

on the 10-pin connector (positive

[+] lead from meter). The proper

ohms resistance is approxi-

mately 26,000 ohms.
NOTE: If the check on gas function lamp is not

correct, verify the wire harness has continuity. If wire

harness is good, replace the upper circuit board.

F. AC MODE LAMP AND SWITCH

NOTE: The following checks should be made on the

upper circuit board and harness assembly BEFORE

replacing the upper circuit board or wiring harness.

These checks are to be done with the wiring harness

REMOVED from the lower circuit board, and the ON-

OFF switch turned to "ON".

With the mode switch (?) manually depressed:

Resistance should be indicated between the brown

terminal on the 10-pin connector (negative [–] lead

from meter) to the

red terminal on the 7-

pin connector (posi-

tive [+] lead from

meter). The proper

resistance is approxi-

mately 26,000 ohms.

7 PIN

10 PIN

VIOLET

BLUE

WHITE

BROWN

10 PIN

7 PIN

10 PIN

RED

BROWN

Advertising