21

DIAGNOSTIC SERVICE MANUAL

DOMETIC® RM7030/RM7732

Refrigerators

7.4

BURNER

The burner is a slotted metal tube located below the flue

tube on the cooling unit. It should be level, and the slots

in the burner should be directly below the flue tube. The

burner should be cleaned periodically, at least once a

year. To clean the burner, remove from the refrigerator

and check for any foreign residue that could cause a

deflection of the gas flow or the flame. Next, soak the

burner in an alcohol based solvent and allow to air dry.

After cleaning, reinstall in the refrigerator.

7.5

FLUE BAFFLE

The flue baffle is designed to concentrate the heat (from

the gas flame) at a certain area of the flue tube. It

should be cleaned periodically, at least once a year. To

clean, remove from the flue tube and check for any

damage, then clean thoroughly.

The length of the flue baffle assembly (flue baffle and

wire) should be 39 inches on RM7030; 40 inches on

RM7732. The flue baffle itself should measure 13/16

inch wide and 6 inches long on RM7030 and RM7732.

The proper position of the baffle above the burner is 1

inch.

7.6

FLUE CAP (RM7030 ONLY)

The flue cap is located at the top of the flue tube and is

attached with a screw. It must be properly attached or

flame outage could occur.

7.7

FLUE TUBE

The flue is a component of the

cooling unit. It must be cleaned

periodically, at least once a year. To

clean, remove flue cap and flue

baffle, then cover the burner and

clean by using a flue brush, Domet-

ic Part No. 0151404001. If the flue

tube becomes coated with scale or

residue from combustion of LP gas,

the efficiency of gas operation

decreases.

NOTE: After cleaning be sure to

reinstall the flue baffle and flue cap.

FLUE

CAP

FLUE

TUBE

SECTION 8

WIRING

8.1

EXTERNAL WIRING

A. 120 Volts AC Connection

The refrigerator is equipped with a three-prong

(grounded) plug for protection against shock hazards

and should be plugged directly into a properly

grounded three-prong receptacle. Do not cut or

remove the grounding prong from this plug.

B. 12 Volt DC Connection

Connection is made to the main terminal block. The

refrigerator must be connected to the battery circuit

with two wires of adequate capacity to avoid voltage

drop.
The wire gauge should be a minimum of 14 gauge.

RM7030 (Poduct No. 921890201 & 921890301)

C. Ignition Lock Connection

In order for the circuit board to perform certain

functions, it must receive a signal when the vehicle

engine is running. The signal wire (16 gauge mini-

mum) should originate at the run terminal of the

ignition switch and connect to the "IGN Lock" posi-

tion on the refrigerator terminal block.
Do not use the body or chassis of the vehicle as a

substitute for either of the two conductors. No other

electrical equipment or lighting should be connected

to the refrigerator circuit.

8.2

INTERNAL WIRING

Check all wires at the connectors to be sure of a proper

and tight connection. Also verify the refrigerator is wired

per the wiring diagram for the exact model you are

working on. See the following typical wiring diagrams.

NOTE: Improper wiring at the lower circuit board could

cause erratic operation and lower circuit board failure.

(Wiring diagrams continued on next page)