Rocktron Intellifex On-Line User Manual

Page 53

Advertising
background image

50

Turn the FUNCTION SELECT control on the Intellifex Online to the "MIDI DUMP/
LOAD" function. This function is available at the most clockwise position of the FUNC-
TION SELECT control in all user presets.

Step 2

MIDI DUMP/LOAD

Turn the PARAMETER SELECT control to the "DUMP USER DATA" position.

Step 3

DUMP USER DATA

Step 4

Start the sequencer recording.

RECORD

Press the STORE button on the Intellifex Online to initiate the user data dump. The Intellifex
Online will display the number of the data string as it is dumped. Data strings 1-80 are the
user presets as described by the preset dump function, while data string 81 is the program
mappings. Data string 82 contains the footswitch types, MIDI channel, mapping status, and
"power on" preset. After all the user data is transmitted, the Intellifex Online will display
"USER DATA DUMPED". The process takes approximately 3 minutes to complete.

Step 5

USER DATA DUMPED

After the Intellifex Online displays "USER DATA DUMPED", stop the sequencer. The
sequencer should have recorded all of the data. Keep the data stored on a disk and
kept in a safe place.

Advertising