Keypad options, Accessing keypad diagnostics, Exiting the installer options – DMP Electronics Security Control Receiver SCS-1R User Manual

Page 24

Advertising
background image

SCS-1R Installation Guide

Digital Monitoring Products

19

OPERATOR’S GUIDE

Keypad Options

KPD KPD

OPT DIAG STOP

Keypad Options (KPD OPT)

To program keypad options, press the left Select key under KPD OPT. The display

changes to CURRENT KEYPAD ADDRESS: # #.

CURRENT KEYPAD

ADDRESS: 01

Current Keypad Address

The keypad must be set to keypad address 01. This is the default setting and should

not be changed.

KEYPAD MODE:

*SUP

UNSUP

Keypad Mode

The keypad can be set for either Supervised or Unsupervised operation. It is

recommended the setting be left at the default Supervised setting.

DEFAULT KEYPAD

MSG:

Default Keypad Message

Press COMMAND to scroll past this option. The keypad does not provide a

programmable Keypad Message.

ARM PANIC KEYS:

PN

EM F1

Arm Panic Keys

The Panic Keys should be disabled. They cannot be used on the membrane keypad. If

an asterisk appears next to one of the options, for example *PN, press the Select key

under the option with the asterisk to remove the asterisk and disable the panic key.

ACTIVATE ZONE 2

SHUNT: NO YES

Zone 2 Shunt

Leave this option set to NO.

ACTIVATE ZONE 3

EXIT: NO YES

Zone 3 Exit

Leave this option set to NO.

4 DIGIT ENTRY

CARDS: NO YES

Entry Cards

Leave this option set to NO.

ALL?: NO YES

DELAY: 2

All?

Leave this option set to NO.

Accessing Keypad Diagnostics

KPD KPD

OPT DIAG STOP

Keypad Diagnostics (KPD DIAG)

The Keypad Diagnostic option allows you to check the display segments and test

individual keys.
Press the Select key under KPD DIAG. The keypad lights all display segments and turns

off LEDs (Power, ACK, Message). A few seconds later the keypad turns the display

off and turns LEDs on. The keypad then alternates between these two states for

approximately two minutes. Press COMMAND at any time to continue.

PRESS KEY TO

TEST

Test Individual Keys

The display changes to PRESS KEY TO TEST. This option allows you to test each

membrane key to ensure it is operating properly. Press and hold each key for about

two seconds. The key number being held appears in the display. Verify the correct

number displays before testing the next key.

Exiting the Installer Options
When done, press the COMMAND key until the display returns to the Keypad Options and Diagnostics screen. Press

the Select key under STOP to exit the Keypad Options and Diagnostics function.