Network line setup – DMP Electronics Security Control Receiver SCS-1R User Manual

Page 29

Advertising
background image

Digital Monitoring Products

SCS-1R Installation Guide

24

OPERATOR’S GUIDE

Send Caller ID Information
Press the far right Select key for YES, which enables the Caller ID information to be

sent. Caller ID sends the phone number that the panel is using to call. Default is NO.

ECHO CANCEL

DISABLE? NO YES

Echo Cancel Disable

Echo Cancellation is technology used by telephone companies to eliminate echo from

voice telephone transmissions. In some cases this technology can interfere with alarm

signals. If you have problems with Echo Cancellation interfering with your signals,

press the far right Select key for YES to turn off the echo cancellers. If you are not

having problems with the telephone company echo cancellation, select NO to leave the

echo cancelers on. Default is NO.

Network Line Setup

NET LINE 20

ENABLE? NO YES

Enable Network Line

The card number is displayed first (Card 2 in the example) followed by the line number

(Line displays as 0 (zero) for the network line of each card). Press the far right Select

key for YES, which enables the network for the selected card. Default is YES. If NO is

selected, the display returns to the Card Number prompt.

LOCAL IP ADDRESS

192.168.000.250

Local IP Address

Enter the LOCAL IP ADDRESS. This is the SCS-104 IP address. The Local IP Address must

be unique and cannot be duplicated. The default value is 192.168.000.250.

LOCAL PORT

2001

Local Port

The LOCAL PORT identifies the port used to communicate messages to and from the

panel. If a setting change is required, enter the new number. Valid range is 1 to

65,535. The default value is 2001.

GATEWAY ADDRESS

000.000.000.000

Gateway Address

Enter the local GATEWAY ADDRESS. You need the Gateway Address to exit your local

network. The default value is 000.000.000.000.

SUBNET MASK:

255.255.255.000

Subnet Mask

Enter the local SUBNET MASK assigned to the SCS-104. The default value is

255.255.255.000.

PASSPHRASE:

Passphrase

In order to communicate using encryption, XR500 Series panels reporting in to the SCS-

104 at the receiver must have a Passphrase. This Passphrase must be programmed into

every panel reporting in to the SCS-104 at the receiver. The SCS-104 installed in the

receiver must also be programmed with the same Passphrase. To clear the passphrase

press any Select Key and then press the COMMAND key.
To enable encryption enter an 8 to 16-character Passphrase using alphanumeric

characters. If you leave the Passphrase blank, the SCS-104 communicates with XR500

Series panels, but the data is not encrypted. The Passphrase is blank by default.

Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that

every XR500 Series panel reporting in to the SCS-104 at the receiver be individually

reprogrammed with a new passphrase.

S16 AND S17

ALWAYS? NO YES

S16 and S17 Always

When NO is selected, the S16 Panel Not Responding message is sent to the automation

computer for each supervised account that has stopped sending check-in messages

unless 50 S16 messages have been generated for different accounts within one

minute. This could occur because the network has failed. Once this occurs, S72

Network Trouble is sent and the receiver stops sending S16 messages to the automation

computer. The receiver sends S73 Network Restored and will begin sending S16

messages after the receiver starts receiving check-in messages again.
When YES is selected, the S16 Panel Not Responding message is always sent to the

automation computer for each supervised account that has stopped sending check-in

messages without regard to the number of accounts generating S16 messages.
When YES is selected, the S17 Panel Response Restored message is sent to the

automation computer each time a supervised account checks in for the first time

after installation. This also occurs at an account’s first check-in after the receiver or

SCS-104 is powered-up. Default is NO.

ACK SUBSTITUTED

MESSAGE? NO YES

Acknowledge Panel Substitution Message

When YES is selected, the SCS-104 replies with an acknowledgment to messages sent by

substituted panels. See the Substitution Code section of the panel programming guide

for the definition of a substituted panel. The SCS-104 generates only one S58 Alarm:

Panel Substitution message to the host automation computer and receiver printer for

SEND CALLER ID

INFO? NO YES