Receiver diagnostics, Remote link programming – DMP Electronics Security Control Receiver SCS-1R User Manual

Page 38

Advertising
background image

SCS-1R Installation Guide

Digital Monitoring Products

33

OPERATOR’S GUIDE

Host Output Baud Rate

Select the baud rate for the Host Output. Select 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400. Default is 9600.

Start Character

Enter the character to be used at the start of a host message. Enter None, 01-12, or 14-31. Default is None.

Use CRC

Select to enable CRC error checking on each message sent to the host. Default is disabled.

Use Sequence Number

Select to enable 1-99 numbering of all messages sent to the host. Default is disabled.

Test Interval (Minutes)

Enter number of minutes between message tests. The test interval can be between 1-60 minutes. Default is 1.

Acknowledge Timeout

Enter the number of seconds (1-15) that the receiver should wait for an acknowledgment from the host before re-

sending the message. Default is 3.

Line Number Length

Enter the number of digits, 0 (zero) through 2, used to report the SCS-1R Receiver signal line number. Default is 0.

Retries to Failure

Enter the number of retries allowed without receiving an acknowledgment from the host before entering a failed

state. This retry number includes the initial message sent to host. The retry range may be from 1-15. Default is 3.

Receiver Diagnostics

The Receiver Diagnostics tab displays the MAC Address, Serial Number, Firmware Version Number, Firmware Date,

Bank Number, Key value, Write Count and DB Version.

Note: The information on this tab is for display only and changes can not be made.

SCS-150 Line Level Diagnostics

Select the SCS-150 Line Level Diagnostics link to display the the diganostics window. This displays the Caller ID

information, ANI/DNIS information and signal Strength level for each line. The card number is listed first: Card 7

in the first example. Range is 1-8. The line number is listed second: Line 1 in the example. Range is 1-4 for all

enabled DD lines.

Remote Link Programming

Programming of the SCS-150 Version 100 or 101 can be performed using Remote Link version 1.47 or higher. SCS-150

Version 103 and higher cannot be programmed using Remote Link. Connect the computer with Remote Link installed

to the 25-pin connector Auxiliary Port on the back of the SCS-1R Receiver using an SCS-204 cable. See Remote Link for

more information.

Note: Each SCS-150 programming section in Remote Link is independent and changes should be sent to the

receiver after programming is completed for each window.