PLL Settings Tab

Description

Value

Parameter

When enabled, the IP core does not instantiate a
PLL locally. Instead, a series of clock connections
are elaborated with the prefix "ext" that should be
connected to an externally generated PLL. This
option allows you to access all of the available
clocks from the PLL, as well as use advanced PLL
features such as clock switchover, bandwidth
presets, dynamic phase stepping, and dynamic
reconfiguration.

The Clock Resource Summary tab guides you to
configure your external PLL.

Use external PLL

Specifies the

inclock

frequency in MHz

Desired inclock frequency

Specifies the closest

inclock

frequency to the

desired frequency that can source the interface.

Actual inclock frequency

Specifies the FPGA/PLL speed grade which
determines the operation range of the PLL.

FPGA/PLL speed grade

When enabled, this parameter exposes the

pll_

areset

port, which you can use to reset the entire

LVDS interface.

Enable pll_areset port

Specifies which clock network the Altera LVDS
SERDES IP core should export an internally
generated coreclock onto.

This feature is not supported in the
current version of the Quartus II
software. However, this can be
manually added using QSF
assignments.

Note:

Core clock resource type

Receiver Settings Tab

Description

Value

Parameter

Bitslip Settings

When enabled, this parameter adds a bitslip block
to the data path of the receiver and exposes the

rx_

bitslip_ctrl

port (one input per channel). Every

assertion of the

rx_bitslip_ctrl

signal adds one

bit of serial latency to the data path of the specified
channel.

Enable bitslip mode

Altera LVDS SERDES IP Core User Guide