Revision history – Altera Shift Register IP Core User Manual

Page 14

Advertising
background image

Comments

Required

Type

Parameter

Constant value loaded when aset is high. If omitted,
defaults to all 1s. The LPM_AVALUE parameter is
limited to a maximum of 32 bits. Altera recommends
that you specify this value as a decimal number for
AHDL designs.

No

Integer/
String

LPM_AVALUE

Constant value that is loaded on the rising edge of clock
when sset is high. If omitted, defaults to all 1s. Altera
recommends that you specify this value as a decimal
number for AHDL designs.

No

Integer/
String

LPM_SVALUE

Allows you to specify Altera-specific parameters in

VHDL Design Files (.vhd)

. The default is “UNUSED”.

No

String

LPM_HINT

Identifies library of parameterized modules (LPM)
entity name in VHDL Design Files.

No

String

LPM_TYPE

Revision History

Changes

Version

Date

New output format. Updated for Arria V, Cyclone V, and Stratix
V devices. Removed outdated content.

2013.05.06

May 2013

Updated table 1-1 to include Stratix III device support.

3.0

December 2006

Updated for Quartus II 6.0 software release.

2.0

August 2006

Updated for Quartus II 4.2 software release.

1.1

July 2005

Initial release.

1.0

March 2005

LPM_SHIFTREG Megafunction

Altera Corporation

Feedback

UG-033105

Revision History

14

2013.03.05

Advertising