Casella CEL Environmental enclosure for Microdust User Manual

Page 2

Advertising
background image

TABLE OF CONTENTS

Chapter . . . . . . . . . . . . . . . . . .

Page

WARNINGS . . . . . . . . . . . . . . . . . . . . . . . 3
BATTERY WARNINGS . . . . . . . . . . . . . . . . . 3

1.

ENVIRONMENTAL ENCLOSURE FOR THE

MICRODUST pro . . . . . . . . . . . . . . . . . . . . 4

1.1

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . 4

1.2

System Overview . . . . . . . . . . . . . . . . . . . . . 5

1.3

Power Supply . . . . . . . . . . . . . . . . . . . . . . . 7

2.

USING THE ENVIRONMENTAL ENCLOSURE . . . . . . 8

2.1

Installation . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.2

Battery Charging . . . . . . . . . . . . . . . . . . . . . . 9

2.3

PUF Filter Adapter . . . . . . . . . . . . . . . . . . . . 10

2.3.1

Storage of PUF Filters . . . . . . . . . . . . . . . . . . 10

2.3.2

Inserting / Removing PUF filters . . . . . . . . . . . . . 11

2.4

Collection Filter Cassette . . . . . . . . . . . . . . . . 11

2.5

Powering Up And Using The System . . . . . . . . . . 11

2.5.1

Checking the Instrument’s Span . . . . . . . . . . . . . 12

2.5.2

Checking Probe Zero . . . . . . . . . . . . . . . . . . . 12

2.5.3

Sampling Pump . . . . . . . . . . . . . . . . . . . . . 12

2.6

Starting a Sample Run . . . . . . . . . . . . . . . . . . 13

3.

THE VORTEX ASPIRATING PUMP . . . . . . . . . .

14

3.1

The Aspirating Pump . . . . . . . . . . . . . . . . . . . 14

3.2

Switching the Pump ON and OFF . . . . . . . . . . . . 14

3.3

Resetting the “Elapsed Minutes” Counter. . . . . . . . 14

3.4

Adjusting The Flow Rate . . . . . . . . . . . . . . . . . 14

3.5

Additional Pump Features . . . . . . . . . . . . . . . . 15

3.6

Service Interval For Key Components. . . . . . . . . . . 16

3.7

Fault Finding . . . . . . . . . . . . . . . . . . . . . . . 16

4.

SERVICE . . . . . . . . . . . . . . . . . . . . . . .

18

5.

TECHNICAL INFORMATION . . . . . . . . . . . . .

19

5.1

The Enclosure . . . . . . . . . . . . . . . . . . . . . . 19

5.1.1

Specification . . . . . . . . . . . . . . . . . . . . . . . 19

5.1.2

Ordering Information . . . . . . . . . . . . . . . . . . . 19

5.2

VORTEX Pump . . . . . . . . . . . . . . . . . . . . . . 19

5.2.1

Specification . . . . . . . . . . . . . . . . . . . . . . . 19

5.2.2

Additional Features . . . . . . . . . . . . . . . . . . . . 19

5.2.3

PUF Filter Spares . . . . . . . . . . . . . . . . . . . . . 20

5.

TECHNICAL INFORMATION

5.1

Enclosure

5.1.1 Specification

Operating temperature range:

+5 to +40

o

C in the absence of

condensation

Storage temperature range:

-25 to +55

o

C

Humidity range:

30 to 90% RH provided there is

no condensation

Storage humidity range:

0 to 90% RH in the absence of

condensation

Size:

410 x 330 x 175 mm

Weight:

7 kg without probe

5.1.2 Ordering Information

Enclosure for U.K.:

176091A

Enclosure for Europe:

176092A

Enclosure for U.S.A.:

176093A

Microdust pro

176000A

Rotameter (optional)

-CM344

5.2

VORTEX Pump

5.2.1 Specification

Flow range

1.5 to 4.5 litres/minute,

Flow control accuracy

±5% for selected flow,

Max. pressure drop

50 cm H

2

O at 2 litres/minute,

25 cm H

2

O at 4.0 litres/minute,

Run time

n/a,

Operating temperature

0 to +40

o

C,

Dimensions

120 x 74 x 50 mm.

5.2.2 Additional Features

¤

Six digit elapsed timer in minutes with 1 minute resolution,

¤

“Pump Running” indicator,

¤

Automatic flow fault indicator and shutdown (due to excessive

pressure drop or blockage),

¤

Low battery warning indicator and bleeper,

¤

Low battery shut down.