4 specification of the fuses, Specification of the fuses – KLING & FREITAG K&F ACCESS T9 User Manual

Page 14

Advertising
background image

User’s Manual

ACCESS SYSTEM

KLING & FREITAG GMBH ©1995-2009

Version 6.0, 17.03.2009

Page 14 of 60

4.1.4

Specification of the Fuses

The fuses in all models have the following identical specifications:

Bussmann S 506

Bussmann S 506

Bussmann S 506

Bussmann S 506----8A slow

8A slow

8A slow

8A slow

When necessary, these fuses may only be replaced with the aforementioned original fuse.

4.1.5

Replacement and Positions of the Short-Circuit Fuses

When the fuse is blown, then the chassis is most likely already ruined, as the fuse just
prevents consequential damage resulting from a short circuit of the chassis.
A disassembly of the chassis is, therefore, unavoidable.

The fuse holder of the subwoofers is mounted on the signal wiring behind the input
connector. The ACCESS subwoofers have 2 fuses; one for each of the parallel operating
chassis.

When replacing the fuse, the lid of the terminal with the signal connectors must be
screwed off to reach the fuse holder.

Warning

Advertising
This manual is related to the following products: