Optional features – Pinnacle Systems CA User Manual

Page 11

Advertising
background image

- A - 3 -

Optional Features

Model CA Cascading Safety Light Curtain

Figure 1: Standard RSD

Figure 2b: Auto Blank

Figure 2c: 52-260 RSD and corresponding chart

= Terminal #1

J Designators = Connectors

F Designators = Fuses

F1 = 1A slo-blo fuse

J1

ForAB/FBkeyswitch

J2

Leftsetofpins

ActivatesLatchingOutputswhenjumpered

J2

CentersetofPins

FactoryUseonly

J2

Rightsetofpins

ActivatesCincinnatiInterfacewhenjumpered

J3

1

.

+24vdcpowerinput(0.1A)

J3

2

Ground

J3

3

CAN_H(Greenwire)

J3

4

CAN_L(Whitewire)

J4

1

InputfromCincinnatiInterfacePress

J4

2

InputfromLatchingOutputResetbutton

J5

FactoryUseonly

Remote Status Display (RSD)

Description: Allows AutoBlank and/or FloatingBlank optional features to be added to the Model SS.
Includes a four character diagnostics / status display.

Operation:

Allows you to view current feature modes and status as well as fault conditions.

The Yellow status light indicates when you are in any blanking mode.

Manual Latching Reset:

Install jumper on the left 2 vertical pins of J2, to enable Manual latching reset feature.

Install a N.O. push button between J4 (right terminal) and +24vdc.

To reset after blocking the guard, you must clear the guard then push the N.O. button.

Cincinnati Interface (manual output Test):

If you apply +24vdc to Pin 1 of J4 (left terminal), the display will show a “CINN” and force the “RED” shutting down
both outputs 1 & 2.

This allows a remote device to manually check that both outputs can and will shut OFF.

Figure 2a: Floating Blank

Advertising