- A - 4 -

Optional Features

Model CA Cascading Safety Light Curtain

MULTI-PYLON (MP)
Description:

Multiple sets of light curtains operating independently

can be modifi ed to operate together to prevent infrared
interference between each other, and optionally to
provide a single Dual Safety Output.

Wiring:

The Pink wire of each Receiver pylon must be connected
together as well as the White wires connected together.

Operation:

Standard= Each curtain uses its own Safety Outputs,
but do not interfere with each other.

Single Output: Blocking 1 curtain will shut down the

Safety Outputs of all connected light curtains.

Remote Status Display (RSD) Continued

The fi rst three numbers displayed represent the fi rst
problem beam on the guard starting from the cable end
of the pylon. The fourth number represents the total
number of beams blocked on the guard. Depending
if your beam spacing is 0.5” or 1.0” you can determine
which board in the pylon is bad.

Defi nitions

BEAM #: Indicates

fi rst blocked beam (from cable

end). (i.e. 64 = 64” up with 1.0” beam
spacing, or 32” up with 0.5” spacing)

TOTAL #: Indicates total number of blocked beams

on the curtain.

(i.e., 1 to 9 beams then A to F = 10 to 15
beams)

The Diagnostics Display has two modes of operation:
Status and Fault. If a fault occurs, the display will scroll
the fault message until the power is removed.

Status Display Messages

Normal Operation

TEST

Testing internal systems

RST

Unit waiting for Push of FN1 (located on
control module power supply board middle
left hand side)

RDY

Normal operation

Obstruction

03 >

15 or more beams blocked starting 3 beams
up from cable end

153

3 beams out starting 15 beams up from
cable end

Floating Blank

FB1 1

beam

fl oat maximum

FB2 2

beams

fl oat maximum

FB21

2 beams fl oat maximum, 1 beam is blocked

OBST

More than 2 separate objects detected in
curtain

Auto Blank

AB3

3 beams programmed in as an Auto Blank
object

PENT

Mode 1 penetration into guard

SIZE

Total number of allowable blanked beams
exceeded during programming

MOVE

Auto Blank object(s) moved, uncovering
beam(s)

Cincinnati Interface

CINN

Guard has de-energized safety relays,
forcing a false blockage mode

Beam # Total#