Appendix “a – Pinnacle Systems CA User Manual

Page 30

Advertising
background image

Appendix “A”

Diagnostics & Troubleshooting

Model CA Cascading Safety Light Curtain

- C - 1 -

Flashing LED(s) indicate a fault has occurred. To
fi nd the fault you must count the number of fl ashes.
If multiple faults have occurred, the lowest number
fl ashed fi rst, followed by the next higher number, after
the last fault is fl ashed the cycle starts over again.

NOTE: The “Remote Status Display” will show the
actual fault message instead of fl ashing LEDs.

Problem:

Yellow LED is ON steady on

Emitter pylon. Red LED fl ashes

every

few

seconds.

Solution:

The CAN data lines (white &

green wires) from both RX and TX

pylons are not connected together.

The CA guard has gone into bottom beam syn-
cronization mode where the RX and TX pylons
donot need to by wired together.

Problem:

No output on 1 or both of the

Safety Outputs (blue and/or brown

wires) are not reading 24vdc when

the guard is GREEN.

Solution:

Check RX pylon wiring. Check

RX pylon internal fuse. Allow unit

to cool down, remove Outputs

Advertising