Specifications

Horizontal scan frequency

:

31.5 kHz

Equivalent interlaced NTSC bandwidth

:

6.75 MHz

Video frequency response

:

±0.5 dB up to 5.5 MHz

Video signal to noise ratio

:

better than –60 dB

Video differential phase

:

better than 0.5

°

Video differential gain

:

better than 0.1 dB

Video output impedance

:

75

Video output complement

:

progressive YPbPr on 75

Ω BNC

Progressive YPbPr standard

:

EIA 770.2 and SMPTE 293M-1996

Y signal levels

:

-300 mV embedded sync, 700 mV peak (ref. blanking)

Pb signal levels

:

±350 mV (ref. blanking)

Pr signal levels

:

±350 mV (ref. blanking)

Video input formats supported

:

NTSC, PAL

Video aspect ratios

:

anamorphic, 16:9

letterboxed, 4:3

pan&scan, 4:3

“pre-shrunk” 4:3 video

(designed to display 4:3 on an anamorphic display)